Calibration of the entire motion sensing and measuring portions of the system is accomplished by placing the sensors on a cam actuated platform. This platform provides a fixed .005 Inch vertical motion at 8 cycles per second. The corresponding meter reading of 5 mils is set In the control unit by adjustment of an individual sensitivity control for each geophone.


All subsequent deflection measurements are thus, in effect, comparisons against this standard deflection. 